Please use this identifier to cite or link to this item: http://localhost:8080/xmlui/handle/123456789/1496
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPraveen, R S-
dc.contributor.authorSobhi Daniel-
dc.contributor.authorPrasada Rao, T-
dc.contributor.authorSampath, S-
dc.contributor.authorRao, K S-
dc.date.accessioned2014-06-09T11:45:33Z-
dc.date.available2014-06-09T11:45:33Z-
dc.date.issued2006-
dc.identifier.citationTalanta 70(2):437-443;15 Sep 2006en_US
dc.identifier.issn0039-9140-
dc.identifier.urihttp://ir.niist.res.in:8080/jspui/handle/123456789/1496-
dc.description.abstractA sensitive and efficient flow injection preconcentration and matrix-separation technique using exfoliated graphite (EG) as column material was developed prior to flame atomic absorption spectrometry (FAAS) determination of palladium(II) in streel/fan blade dust and rock samples. The method is based on the sorption of palladium(II)-diethylammonium dithiocarbamate chelate (which was found to be better among various thioligands) complex on to EG material and its subsequent elution with acidified methanol (0.01 M HCl in methanol). Using 8 ml of the sample, the detection limit achieved was 1.0 mu g l(-1). The accuracy of the method developed was checked by analysing certified reference material SARM-7. The precision obtained for five successive determination of 100 mu g l(-1) of palladium(II) was 2.4%. The performance of EG material was compared with allotropes of carbon in terms of pH, chelate concentration, weight of column material, sensitivity enhancement (w.r.t. conventional FAAS), detection limit, calibration range, selectivity and precision. Furthermore, performance of the EG material packed column was compared with commercially available C-18 bonded silica gel/alumina columns for on-line FIA-FAAS determination of palladium(II).en_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.subjectPalladiumen_US
dc.subjectExfoliated graphiteen_US
dc.subjectAllotropes of carbonen_US
dc.subjectFlow injectionen_US
dc.subjectFAASen_US
dc.subjectRocksen_US
dc.subjectPlatinum group elementsen_US
dc.subjectImmobilized silica gelen_US
dc.subjectSilveren_US
dc.subjectGolden_US
dc.subjectWateren_US
dc.titleFlow injection on-line solid phase extractive preconcentration of palladium(II) in dust and rock samples using exfoliated graphite packed microcolumns and determination by flame atomic absorption spectrometryen_US
dc.typeArticleen_US
Appears in Collections:2006

Files in This Item:
File Description SizeFormat 
2006_0091.PDF
  Restricted Access
179.36 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.