dc.description.abstractA two-dimensional biomimetic optrode for the detection and quantification of uranium in natural waters was fabricated. The sensing element was designed by the inclusion of uranyl ion imprinted polymer particles into polymethyl methacrylate followed by casting a thin film on a glass slide without any plasticizer. The ion imprinted polymer material was prepared via covalent immobilization of the newly synthesised ligand 4-vinyl phenylazo-2-naphthol by thermal polymerization. Operational parameters such as pH, response time and the amount of sensing material were optimized. The response characteristics of the imprinted and the corresponding non-imprinted polymer inclusion optrodes of uranium were compared under optimum conditions. The imprinted polymer inclusion optrode responds linearly to uranium in the concentration range 0-1.0 mu g mL(-1) with a detection limit of 0.18 mu g mL(-1), which is much better than the solution studies using 4-vinyl phenylazo-2-naphthol (1.5 mu g mL(-1)). Triplicate determinations of 100 mu g of uranium(VI) present in 250 mL of solution gave a mean absorbance of 0.018 with a relative standard deviation of 8.33%. The superior sensitivity of imprinted polymer inclusion optrode is exemplified by lower detection limits and broader dynamic range over non-imprinted polymer inclusion optrode. The developed imprinted polymer inclusion optrode was found to give stable and precise response for 3 months and can be used without any loss in sensitivity. The applicability for analysing ground, lake and tap-water samples collected in the vicinity of uranium deposits was successfully demonstrated.en_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.subjectTwo-dimensional sensoren_US
dc.subjectOptrodeen_US
dc.subjectUraniumen_US
dc.subjectDeterminationen_US
dc.subjectSolid phase extractionen_US
dc.subjectIon imprinted polymeren_US
dc.subjectMolecularly imprinted polymersen_US
dc.subjectHeavy-metal ionsen_US
dc.subjectOptical sensorsen_US
dc.subjectPreconcentrationen_US
dc.subjectUraniumen_US
dc.subjectRecognitionen_US
dc.titleDesign of two-dimensional biomimetic uranyl optrode and its application to the analysis of natural watersen_US