Please use this identifier to cite or link to this item: http://localhost:8080/xmlui/handle/123456789/2139
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPrasad, K-
dc.contributor.authorGopikrishna, P-
dc.contributor.authorKala, R-
dc.contributor.authorPrasada Rao, T-
dc.contributor.authorNaidu, G R K-
dc.date.accessioned2016-01-18T07:42:56Z-
dc.date.available2016-01-18T07:42:56Z-
dc.date.issued2006-
dc.identifier.citationTalanta 69(4):938-945;15 Jun 2006en_US
dc.identifier.issn0039-9140-
dc.identifier.urihttp://ir.niist.res.in:8080/jspui/handle/123456789/2139-
dc.description.abstractThis article compares the solid phase extraction (SPE) and coprecipitative preconcentration of cadmium and lead from dilute aqueous solutions as a function of pH and weight of chelating agent. SPE enriches cadmium and lead over a wider pH range (6.0-8.0) and requires lower weight of DBQ chelate embedded benzophenone. Among the quinoline-8-ol and its dihatoderivatives, DBQ embedded benzophenone allows quantitative enrichment over a wide pH range (6.0-8.0) for both cadmium and lead unlike DCQ (similar to 6.5 for Cd and 6.5-7.0 for Pb), DBQ was preferred. The calibration plots were rectilinear over the concentration range of 0.1-50 and 2.5-200 mu g l(-1) of cadmium and lead with detection limits of 0.1 and 2.0 mu g l(-1), respectively, which are 400 times lower than the direct FAAS method. The precision of the developed procedure is good as it provides relative standard deviation values of 2.20 and 2.45% during five replicate determinations of 2 and 25 mu g l(-1) of cadmium and lead, respectively. The accuracy of the developed procedure was tested by analyzing certified reference materials (CRM's) of soil and marine sediment samples supplied by IAEA, Italy and NRC, Canada, respectively. Furthermore, the developed procedure has been successfully used for the speciative determination of cadmium and lead in soil samples collected from the vicinity of industries in Indiaen_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.subjectSolid phase extractionen_US
dc.subjectCoprecipitationen_US
dc.subject5,7-dibromoquinoline-8-olen_US
dc.subjectBenzophenoneen_US
dc.subjectPreconcentrationen_US
dc.subjectSoilsen_US
dc.subjectChemical speciationen_US
dc.subjectFAASen_US
dc.titleSolid phase extraction vis-a-vis coprecipitation preconcentration of cadmium and lead from soils onto 5,7-dibromoquinoline-8-ol embedded benzophenone and determination by FAASen_US
dc.typeArticleen_US
Appears in Collections:2006

Files in This Item:
File Description SizeFormat 
2006_0086.PDF
  Restricted Access
312.84 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.