Please use this identifier to cite or link to this item:
http://localhost:8080/xmlui/handle/123456789/2139
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Prasad, K | - |
dc.contributor.author | Gopikrishna, P | - |
dc.contributor.author | Kala, R | - |
dc.contributor.author | Prasada Rao, T | - |
dc.contributor.author | Naidu, G R K | - |
dc.date.accessioned | 2016-01-18T07:42:56Z | - |
dc.date.available | 2016-01-18T07:42:56Z | - |
dc.date.issued | 2006 | - |
dc.identifier.citation | Talanta 69(4):938-945;15 Jun 2006 | en_US |
dc.identifier.issn | 0039-9140 | - |
dc.identifier.uri | http://ir.niist.res.in:8080/jspui/handle/123456789/2139 | - |
dc.description.abstract | This article compares the solid phase extraction (SPE) and coprecipitative preconcentration of cadmium and lead from dilute aqueous solutions as a function of pH and weight of chelating agent. SPE enriches cadmium and lead over a wider pH range (6.0-8.0) and requires lower weight of DBQ chelate embedded benzophenone. Among the quinoline-8-ol and its dihatoderivatives, DBQ embedded benzophenone allows quantitative enrichment over a wide pH range (6.0-8.0) for both cadmium and lead unlike DCQ (similar to 6.5 for Cd and 6.5-7.0 for Pb), DBQ was preferred. The calibration plots were rectilinear over the concentration range of 0.1-50 and 2.5-200 mu g l(-1) of cadmium and lead with detection limits of 0.1 and 2.0 mu g l(-1), respectively, which are 400 times lower than the direct FAAS method. The precision of the developed procedure is good as it provides relative standard deviation values of 2.20 and 2.45% during five replicate determinations of 2 and 25 mu g l(-1) of cadmium and lead, respectively. The accuracy of the developed procedure was tested by analyzing certified reference materials (CRM's) of soil and marine sediment samples supplied by IAEA, Italy and NRC, Canada, respectively. Furthermore, the developed procedure has been successfully used for the speciative determination of cadmium and lead in soil samples collected from the vicinity of industries in India | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier | en_US |
dc.subject | Solid phase extraction | en_US |
dc.subject | Coprecipitation | en_US |
dc.subject | 5,7-dibromoquinoline-8-ol | en_US |
dc.subject | Benzophenone | en_US |
dc.subject | Preconcentration | en_US |
dc.subject | Soils | en_US |
dc.subject | Chemical speciation | en_US |
dc.subject | FAAS | en_US |
dc.title | Solid phase extraction vis-a-vis coprecipitation preconcentration of cadmium and lead from soils onto 5,7-dibromoquinoline-8-ol embedded benzophenone and determination by FAAS | en_US |
dc.type | Article | en_US |
Appears in Collections: | 2006 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2006_0086.PDF Restricted Access | 312.84 kB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.