DSpace Repository

Flow injection on-line solid phase extractive preconcentration of palladium(II) in dust and rock samples using exfoliated graphite packed microcolumns and determination by flame atomic absorption spectrometry

Show simple item record

dc.contributor.author Praveen, R S
dc.contributor.author Sobhi Daniel
dc.contributor.author Prasada Rao, T
dc.contributor.author Sampath, S
dc.contributor.author Rao, K S
dc.date.accessioned 2014-06-09T11:45:33Z
dc.date.available 2014-06-09T11:45:33Z
dc.date.issued 2006
dc.identifier.citation Talanta 70(2):437-443;15 Sep 2006 en_US
dc.identifier.issn 0039-9140
dc.identifier.uri http://ir.niist.res.in:8080/jspui/handle/123456789/1496
dc.description.abstract A sensitive and efficient flow injection preconcentration and matrix-separation technique using exfoliated graphite (EG) as column material was developed prior to flame atomic absorption spectrometry (FAAS) determination of palladium(II) in streel/fan blade dust and rock samples. The method is based on the sorption of palladium(II)-diethylammonium dithiocarbamate chelate (which was found to be better among various thioligands) complex on to EG material and its subsequent elution with acidified methanol (0.01 M HCl in methanol). Using 8 ml of the sample, the detection limit achieved was 1.0 mu g l(-1). The accuracy of the method developed was checked by analysing certified reference material SARM-7. The precision obtained for five successive determination of 100 mu g l(-1) of palladium(II) was 2.4%. The performance of EG material was compared with allotropes of carbon in terms of pH, chelate concentration, weight of column material, sensitivity enhancement (w.r.t. conventional FAAS), detection limit, calibration range, selectivity and precision. Furthermore, performance of the EG material packed column was compared with commercially available C-18 bonded silica gel/alumina columns for on-line FIA-FAAS determination of palladium(II). en_US
dc.language.iso en en_US
dc.publisher Elsevier en_US
dc.subject Palladium en_US
dc.subject Exfoliated graphite en_US
dc.subject Allotropes of carbon en_US
dc.subject Flow injection en_US
dc.subject FAAS en_US
dc.subject Rocks en_US
dc.subject Platinum group elements en_US
dc.subject Immobilized silica gel en_US
dc.subject Silver en_US
dc.subject Gold en_US
dc.subject Water en_US
dc.title Flow injection on-line solid phase extractive preconcentration of palladium(II) in dust and rock samples using exfoliated graphite packed microcolumns and determination by flame atomic absorption spectrometry en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account