DSpace Repository

Design and development of imprinted polymer inclusion membrane-based field monitoring device for trace determination of phorate (O,O-diethyl S-ethyl thiomethyl phophorodithioate) in natural waters

Show simple item record

dc.contributor.author Prasad, K
dc.contributor.author Prathish, K P
dc.contributor.author Mary Gladis, J
dc.contributor.author Naidu, G R
dc.contributor.author Prasada Rao, T
dc.date.accessioned 2014-10-18T06:15:03Z
dc.date.available 2014-10-18T06:15:03Z
dc.date.issued 2007
dc.identifier.citation Electroanalysis 19(11):1195-1200;Jun 2007 en_US
dc.identifier.issn 1040-0397
dc.identifier.uri http://ir.niist.res.in:8080/jspui/handle/123456789/1680
dc.description.abstract A biomimetic potentiometric field monitoring device was developed for the trace determination of phorate (O,O-diethyl S-ethyl thiomethyl phophorodithioate) in natural waters. The sensing element was fabricated by the inclusion of phorate imprinted polymer materials in the polyvinyl chloride (PVC) matrix. The sensor surface can be reused without conditioning unlike most other conventional sensors. Operational parameters such as amount and nature of plasticizers sensing material, pH and response time were optimized. The response characteristics of the non-imprinted (NIPIM) and imprinted polymer inclusion membrane (IPIM) sensors for phorate were compared under optimum conditions. The IPIM sensor responds linearly to phorate in the concentration in the ranges 1. x 10(-9) to 1 x 10(-6) M and 1 x 10(-6) to 1 x 10(-5) M of different slopes with a detection limit of 1 x 10(-9) M. The selectivity was tested with various common organophosphorous (OP) pesticides and herbicides. In addition to superior sensitivity and selectivity of IPIM over NIPIM-based sensor, IPIM-based phorate sensor was found to be stable for 3 months and can be used for more than 40 times without any loss in sensitivity. The applicability for analyzing ground, river and tap-water samples was successfully demonstrated via recovery studies. en_US
dc.language.iso en en_US
dc.publisher Wiley en_US
dc.subject Phorate en_US
dc.subject Imprinted polymer inclusion membrane sensor en_US
dc.subject Potentiometry en_US
dc.subject Organophosphorous pesticides en_US
dc.subject Natural waters en_US
dc.subject Ion-selective electrodes en_US
dc.title Design and development of imprinted polymer inclusion membrane-based field monitoring device for trace determination of phorate (O,O-diethyl S-ethyl thiomethyl phophorodithioate) in natural waters en_US
dc.type Article en_US
niist.citation


Files in this item

This item appears in the following Collection(s)

  • 2007
    Research Papers published in journals in year 2007

Show simple item record